Dear customers, all prices includes VAT 20%.

Product Description:

Three Phase Inverter Solax X3-MIC-6K-G2 6KW

 

High-effciency
Maximum effciency is up to 98.3%
Low startup voltage, ultrawide MPPT voltage range
200% oversizing, 110% overloading output (Except 15kW model)
In-built global MPP scan for higher yield effciency
Safe
IP66 protection
Integrated SPD protection on both AC&DC
Smart
Built-in export power control
Remote setting and upgrading
24h monitoring and maintenance (Optional)
Intelligent load management - heat pump (Adapter Box required)
Multiple monitoring methods supported, Optional: WiFi/LAN/4G
Economic
Ultra-high power density
Max. MPP current per string is 16A, support high power solar panels

 

DC INPUT    
Max. PV array input power [Wp] : 1200
Max. PV input voltage [V] : 1000
Start startup voltage [V] : 150
Nominal input voltage [V] : 640
MPP tracker voltage range [V] : 120~980
No. of MPP trackers : 2
Strings per MPP tracker : 1
Max. PV input current [A] : 16/16
Isc PV Array Short Circuit current [A] : 20/20
     
AC OUTPUT    
Rated AC output power [kW] : 6000
Rated AC output current [A] : 9.1/8.7
Max. AC output apparent power [VA] : 6600
Max. AC output current [A] : 9.6
AC voltage range [V] : 220/380V, 230/400V, 3/(N)/PE; (95-285V)
AC frequency range [Hz] : 50/60; ±5
Power Factor range : 0.8 leading ~ 0.8 lagging
THDi (Rated power) [%] : <3
     
SYTEM DATA    
Max. efficiency [%] : 98.30
Euro efficiency [%] : 97.80
Standby consumption (Night) [W] : <3
Ingress protection : IP66
Operating ambient temperature range [°C] : -30~+60 (Derating above 45)
Max. operation altitude [m] : 4000 (Derating above 3000)
Relative humidity [%] : 0~100
Typical noise emission [dB] : <45
Storage temperature [°C] : -30~+60
Dimensions (W×H×D) [mm] : 342×434×144.5
Weight [kg] : 17
Cooling concept : Natural cooling
Communication interfaces : USB / RS485 / DRM, Optional: Meter
Optional monitoring dongle : Pocket WiFi/LAN/4G
Display : 2 x LED + LCD (16 x 2) / APP
     
PROTECTION    
Over/under voltage protection : YES
DC isolation protection : YES
Grid monitoring : YES
DC injection monitoring : YES
Residual current detection : YES
Anti-islanding protection : YES
Over Temp protection : YES
SPD (DC/AC) : Type II / Type II
AC auxiliary power supply (APS) : Optional
Arc-fault circuit interrupter (AFCI) : Optional
     
STANDARD    
Safety : IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004
EMC : IEC/EN 61000; NB/T 32004
Certification : VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004

All Products are NEW with Warranty
All prices includes VAT 20%

Parse Time: 0.055s